Do lighting circuits need to be AFCI protected?
AFCI requirements. The NEC requires that virtually all branch circuits for lighting and receptacles in a home must have arc-fault circuit-interrupter (AFCI) protection. This is a form of protection that guards against sparking (arcing) and thereby reduces the chance of fire.
What circuits require arc fault protection?
AFCI protection is currently required for all 15 and 20 amp branch circuits providing power to outlets* in residential family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, and similar rooms or areas.
Are arc fault breakers required in garage?
The 2017 National Electrical Code (NEC) requires the protection of an arc fault circuit interrupter (AFCI) for 15 and 20 amp circuits in all newly built residential areas, but they are not needed in bathrooms, garages, or outdoor areas.
Do garage lights need to be GFCI protected?
NEC 210.8. 2 requires all outlets in a garage to be GFCI protected so if your lights are connected by an outlet they need GFCI protection if they are hard wired they do not require GFCI protection.
Where is AFCI not required?
AFCI protection is not required for outlets located outside or in garages or bathroom areas. (B) All 15A or 20A, 120V branch circuits supplying outlets in dormitory unit bedrooms, living rooms, hallways, closets, bathrooms, or similar areas.
Do lights need to be GFCI protected?
You might not be aware of it, but your bathroom lights could pose a safety hazard in the event that you have an electrical short. This is because GFCI (ground fault circuit interruption) protection is only required for outlets and switches, not light fixtures unless they are above the shower area.
Do all outlets in garage need to be GFCI?
GFCI protection is required for 125-volt to 250-volt receptacles supplied by single-phase branch circuits rated 150 volts or less to the ground. GFCI receptacles are required in bathrooms, garages, crawl spaces, basements, laundry rooms and areas where a water source is present.
Do garage receptacles need to be AFCI?
The shorter list is areas not requiring AFCI protection: unfinished basement areas, attached or detached garages, outdoor lighting and receptacles, accessory buildings and bathrooms are not required to be fed via AFCI protected circuit.
Where is AFCI not needed?
Can GFCI and lights on same circuit?
Electrically there is no problem with powering the light with the hot and neutral feed to the GFCI receptacle. You could use pigtails to the receptacle line (and not use the load connection) and to the light switch so the lights would’t go out if the GFCI receptacle tripped.
Can Romex be exposed in a garage?
When running Romex through garages, it is important that it is insulated to ensure that the wire doesn’t get damaged. As for the question of whether Romex can touch insulation or not, yes, it can. However, it is important to remember that the insulation shouldn’t come in contact with the copper inside.
What is the Best Lighting for a woodworking workshop?
The general consensus I found for woodworking and garage workshop settings seems to be at 5,000K, while some prefer a tad warmer, around 4,000K. Next you want to look at the CRI which is the color rendering index, and this is how accurately the lighting will allow you to see colors.
What is the purpose of AFCI wiring?
The function of the AFCI is to protect the branch circuit wiring from dangerous arcing faults that could initiate an electrical fire. AFCI and GFCI technologies can co-exist with each other and are a great complement for the most complete protection that can be provided on a circuit. Are there any wiring and installation guidelines?
What circuits are covered by AFCI protection?
All 120-volt, single-phase, 15- and 20-ampere branch circuits supplying outlets installed in dormitory unit bedrooms, living rooms, hallways, closets, bathrooms and similar rooms shall be protected” by AFCI devices. Circuits that provide more than 20 amps or more than 120 volts (208 / 240 volts circuits) are also exempted from AFCI protection.